HP-UX 11i Version 1.6 Installation and Configuration Guide

Known Problems and Troubleshooting
Common Install Error and Warning Messages
Appendix B 105
"Obsolete.DISKLESS,r=B.11.22,a=HP-UX_B.11.22_IA/PA,v=HP"; it
is not available from depot or root "gold15:/".
* Could not apply the software selection
"Obsolete.INSTANTIGNITE,r=B.11.22,a=HP-UX_B.11.22_IA/PA,v=HP";
it is not available from depot or root "gold15:/".
A software selection titled Obsolete.XYZ is only installed if a system is
being updated from one release to the next and is used to remove
obsolete products from the system. Because there are no obsolete
products to remove during a cold install, these software selections are
excluded, generating a warning message.
This message is strictly informational and no action is required.
VxVM Warning
The install.log file may contain the following message:
* Configure_Disks: Begin
* Will install B.11.22 onto this system.
* Starting VxVM
* Creating VxVM Disk "c2t1d0s2" (0/18/1/0/0.0.1.0).
* Adding disk "c2t1d0s2" to rootdg.
* Enabling VxVM
07/25 18:20:01: vxvm:vxconfigd: WARNING: File
/etc/vx/array.info doesn't exist.
Generating file /etc/vx/array.info.
This message does not require action. The log file is located at:
/var/opt/ignite/local/install.log