HP-UX 11i Version 1.6 Installation and Configuration Guide
Known Problems and Troubleshooting
Install Known Problems
Appendix B 101
after installing the HP-UX 11iv1.6 OS on your Itanium-based system to
eliminate a problem when you execute 64-bit PA applications. Only
64-bit PA ONC applications use this library.
Use the following command:
$ ln -s /usr/lib/pa20_64/libstraddr.1
/usr/lib/pa20_64/libstraddr.so.1
After executing the command, enter the following command for
verification:
$ ll /usr/lib/pa20_64/libstraddr*
The sample output should appear as follows:
-r-xr-xr-x 1 bin bin 14616 Jul 16 12:30
/usr/lib/pa20_64/libstraddr.1
lrwxrwxrwx 1 root sys 12 Jul 24 12:44
/usr/lib/pa20_64/libstraddr.so.1 -> libstraddr.1
Known Issues With OE Media Install Tool and
Network Depots
The Ignite-UX install tool on the OE media supports the use of network
depots. However, network depots must match the media depots for the
choices in the install tool to work properly.
The Ignite-UX documentation also explains the setup and use of network
depots without using the OE media for each installation. See the
following web site for information on the Ignite-UX product:
http://software.hp.com/products/IUX