HP-UX 11i Version 1 Installation and Update Guide, June 2004

Updating to HP-UX 11i v1
How to Update to HP-UX 11i v1
Chapter 6126
After migrating your directory server database to NDS 6.02, you should
remove the old version of NDS using swremove. For example:
/usr/sbin/swremove J3667AA
Update Selectable Software
To update to HP-UX 11i v1 and include additional selectable software,
such as Ignite-UX (see Table 4-5, “HP-UX 11i v1 Selectable Software
Bundles (all OEs),” on page 79 for a listing of other selectable bundles.
For information on selectable network drivers, see the HP-UX 11i v1
Release Notes, at http://docs.hp.com/hpux/os/11i/index.html.
Step 1. As root, enter:
•CD-ROM: /usr/sbin/update-ux -x /cdrom B5725AA
•DVD: /usr/sbin/update-ux -x /dvdrom B5725AA
In the above command, update-ux installs the core HP-UX 11i v1 OS
bundles listed in Table 4-2, “HP-UX 11i v1 Core Software Bundles,” on
page 74, plus the Ignite-UX server bundle, B5725AA.
Step 2. Complete any post-install configuration explained in the HP-UX 11i v1
Release Notes available on the Instant Information CD and on
http://docs.hp.com/hpux/os/11i. In this example, to complete the
Ignite-UX server installation, see the Ignite-UX Administration Guide.
Step 3: Verify the Update
To verify the success of your update, review the update messages logged
in /var/adm/sw/swagent.log. For more information on how to verify
your update, see Chapter 7, “Verifying System Migration,” on page 127.