HP-UX 11i Version 1 Installation and Update Guide, December 2004

Known Problems and Troubleshooting
Update Known Problems
Appendix B146
HP Apache May Hang
On Reboot after
System Update from
Golden System Image
(GSI) Depot
When upgrading from a GSI-installed system containing an
OE with HP Apache 2.0, some systems may hang while
attempting to shutdown the Apache Web Server. The problem
is caused by an obsolete PID from the httpd daemon being
copied from the GSI Golden Image Depot to the client system.
You may be affected if you are upgrading from a GSI HP-UX
11.0 Depot containing HP Apache 2.0 to HP-UX 11i v1.
GSI Depot (Server):
1. Shut down your HP Apache Web Server before creating
the GSI Depot by typing
/opt/hpapache2/bin/apachectl stop
2. Verify that the following file has been deleted:
/opt/hpapache2/logs/httpd.pid
Client System:
Delete the following file (if present) after installing the GSI
Depot and before an update install:
/opt/hpapache2/logs/httpd.pid
MLIB 8.3 Produces
Warning During
Update
When updating from MLIB 8.1 (or earlier) to MLIB 8.3 the
following warning may appear in the
/var/adm/sw/swagent.log:
WARNING: Incomplete definition for the product
"MLIBPROD", beginning at line 44452. The following
attributes are not defined:filesets the filesets
contained in the product
You can disregard this warning message; there is no problem
with the installation.
Table B-3 Known Update Problems (Continued)
Problem Description/Action