HP-UX 11i Version 1 Installation and Update Guide, December 2003

Updating to HP-UX 11i v1
How to Update to HP-UX 11i v1
Chapter 6138
For instructions on migrating your directory server database to version
6.02 after installing the new version of NDS, refer to the Netscape
document, Netscape Directory Server Administrator’s Guide, available on
the Netscape web site:
http://www.netscape.com
After migrating your directory server database to NDS 6.02, you should
remove the old version of NDS using swremove. For example:
/usr/sbin/swremove J3667AA
Update Selectable Software
To update to HP-UX 11i v1 and include additional selectable software,
such as Ignite-UX (see Table 4-6, “HP-UX 11i v1 Selectable Software
Bundles (all OEs),” on page 85 and Table 4-7, “HP-UX 11i v1 Selectable
Network Drivers,” on page 86 for a listing of other selectable bundles:
Step 1. As root, enter:
•CD-ROM: /usr/sbin/update-ux -x /cdrom B5725AA
•DVD: /usr/sbin/update-ux -x /dvdrom B5725AA
In the above command, update-ux installs the core HP-UX 11i v1 OS
bundles listed in Table 4-2, “HP-UX 11i v1 Core Software Bundles, on
page 79, plus the Ignite-UX server bundle, B5725AA.
Step 2. Complete any post-install configuration explained in the HP-UX 11i v1
Release Notes available on the Instant Information CD and on
http://docs.hp.com/hpux/os/11i. In this example, to complete the
Ignite-UX server installation, see the Ignite-UX Administration Guide.
Step 3: Verify the Update
To verify the success of your update, review the update messages logged
in /var/adm/sw/swagent.log. For more information on how to verify
your update, see Chapter 7, “Verifying System Migration,” on page 139.