HP-UX 11i v1 Installation and Update Guide, December 2006
Known Problems and Troubleshooting
Common Install and Update Error and Warning Messages
Appendix B 157
swinstall Analysis
Error
The analysis phase failed while installing from the
first depot. See the /var/adm/sw/swagent.log for
details.
The swinstall analysis on software from HP-UX 11i v1 CD1
failed and update-ux quit. Correct the indicated problem and
run the command again.
Post-update swverify
Error
After updating your system to an HP-UX 11i v1 OE, run
swverify to ensure that all application software previously
on your system is still compatible with the new OS. If you get
an error like this:
The product "xyz,l=/,r=B.xx.xx" is not compatible
with this system’s architecture or operating system.
The indicated software (
xyz
) has not been updated to HP-UX
11i. To update the software, mount the HP-UX 11i v1
Applications CD that contains the software and install the
new version using the swinstall command. For more details,
see Chapter 7.
Root (/) Volume Lock
Error
If update-ux quits after you extended a volume size, you may
see an error containing these lines:
ERROR: The command: /var/adm/sw filter
/var/adm/sw/update-ux/swinstall...
This error will be logged in /var/adm/sw/swinstall.log:
Error: Cannot lock “/” because another command hold a
conflicting lock ...
This error indicates that other processes have locked the root
volume, preventing update-ux from completing a successful
update.
Wait 10 minutes and retry the update-ux command again.
Table B-3 Common Install and Update Error and Warning Messages
Problem Description/Action