HP-UX 11i v1 Installation and Update Guide, December 2006

Known Problems and Troubleshooting
Known Install Problems
Appendix B138
Visual Conference
Product Does Not
Install or Update
with CD Media
On the latest release of HP-UX11i v1, a checkinstall script
error causes the Visual Conference product to be excluded from
the TCOE Operating Environment.
If you are installing or updating to the latest TCOE Operating
Environment from CD media (not DVD) you will be affected.
You must reinstall the Visual Conference product after you’ve
completed your cold install or update using swinstall.
xntpd Fails to Start on
Reboot After
Installing GOLDQPK11i
Patch Bundle
After installing the GOLDQPK11i patch bundle, xntpd may fail
to start after the initial reboot of the system.
In your syslog.log file, you may encounter a similar message:
Sep 23 14:46:23 <system_name>
xntpd[1812]: tickadj = 625, tick = 10000,
tvu_maxslew = 61875
Sep 23 14:46:23 <system_name> xntpd[1812]:
precision = 6 usec
Sep 23 14:46:23 <system_name>
xntpd[1812]: bind() fd 4, family 2, port 123,
addr 00000000, in_classd=0 flags=1 fails:
Address already in use
You might find a similar message in your rc.log file:
Start time synchronization
Output from ‘/sbin/rc2.d/S660xntpd start’:
23 Sep 14:46:23 ntpdate[1810]:
the NTP socket is in use,exiting xntpd
To resolve this problem:
•Stop xntpd:
/sbin/init.d/xntpd stop
•Verify xntpd is down:
ps -ef | grep xntpd
•Start xntpd
/sbin/init.d/xntpd start
Table B-1 Known Install Problems (Continued)
Problem Description/Action