HP-UX 11i September 2002 Release Notes
nPartition (Hard Partition) Systems
Partition Manager (parmgr)
Chapter 4
51
• A more meaningful error message is displayed when a non-root user attempts to
start Partition Manager.
• When launching Partition Manager from a PC web browser, a graphic displayed in
the initial launch page has been corrected.
• If all cells currently assigned to a partition are removed, and others are added, an
incorrect message is no longer displayed.
• Partition Manager no longer warns about the state of the “Failure Usage” flag when
removing a cell from a partition.
• The Modify Partition dialog now checks for valid partition data and refreshes the
display, ensuring that compatibility checks are accurate.
• The Cell Details dialog now lists DIMMs using the same identification codes that are
printed on the cell board.
• The following have been fixed:
— an error preventing the retrieval of the list of disks attached to an I/O card
— an error preventing the deletion of the local partition
• New problem checkers report:
— active partitions with inactive cells that do not have “Use on Next Boot” set to
“no.”
— any HDCI errors that have occurred
• Messages and online help have been improved for the following:
— deleting a partition
— deleting cells from a partition
— when the GSP is locked or has pending actions
— Confirm Modify Partition dialog
— Online Addition/Replacement of an I/O card