HP-UX 11i September 2001 Release Notes

Hard Partition Systems
Partition Manager (parmgr) (new at 11i original release)
Chapter 2
35
Summary of Changes
Empty cell slots and empty or blocked I/O chassis slots are no longer listed as
Available Resources; they are now listed under a separate category: “Empty
Cell/Chassis Slots.
The printed output of I/O Details and I/O Slot property sheets has been reformatted
for improved readability.
•APrint button was added to the Card Critical Resource Analysis dialog.
The HA status of the I/O fans in Superdome CPU cabinets is now reported as “N/A,
since this information is not made available by system firmware.
A new problem checker reports active partitions with inactive cells that do not have
“Use on Next Boot” set to “no.
A new problem checker reports any HDCI errors that have occurred.
Complex profile locks are now freed after an unlock failure.
An error preventing the retrieval of the list of disks attached to an I/O card was fixed.
The messages and online help displayed while deleting cells from a partition were
improved to reduce confusion.
The messages and online help displayed while deleting a partition were improved to
reduce confusion.
Additional PCI class codes were made available for use in I/O Details filters.
•AShow Details button was added to the Delete Partition dialog, allowing you to
review, save, or print the partition details prior to deletion.
An error preventing the deletion of the local partition was fixed.
Partition Manager is now able to work around certain errors that used to be fatal (for
example, a cell reports a fatal firmware error), Warning messages are displayed, but
you can choose to continue despite the error.
Partition Manager now flashes the amber attention LEDs, instead of setting them to
a steady on state (in accordance with the new PCI standard specification). See “New
Attention Indicator Behavior (updated for September 2001)” on page 37.
Messages and help displayed when the GSP is locked or has pending actions have
been improved to reduce confusion.
Messages and help displayed during Online Addition/Replacement of an I/O card
have been improved to reduce confusion.
Double-clicking on a cell or I/O chassis in the Create Partition Summary window now
displays details (equivalent to clicking Show Details).
CPU Type is now formatted as a hex value in the Cell Details display.
When attempting to power-on an I/O chassis, the Modify Partition task now
power-cycles the cell connected to the chassis, instead of attempting (and failing) to
power-on the chassis directly.
A more meaningful error message is displayed when a non-root user attempts to start
Partition Manager.
When launching Partition Manager from a PC web browser, a graphic displayed in
the initial launch page has been corrected.