HP-UX 11i Release Notes (December 2000)
HP-UX 11i Operating Environments
HP-UX 11i Operating Environment (new)
Chapter 4 81
measurement software will correctly measure the active processors only.
MeasureWare and GlancePlus fall in the category of working correctly.
The system call pstat_getdynamic() returns a structure which
contains the fields psd_proc_cnt. This field was previously always equal
to psd_max_proc_cnt. However, now that processors can be deallocated,
psd_proc_cnt can be less than psd_max_proc_cnt. Some products and
commands which use these fields have done so incorrectly.
For example, given a system with eight processors four of which are
deallocated, psd_proc_cnt will contain four and psd_max_proc_cnt will
contain eight. Previously, the fixes to mpctl and pstat, psd_proc_cnt
would contain eight.
Alternatives iCOD customers are required to assess if their
applications function correctly with iCOD. A workaround is available to
run iCOD systems in an "offline" activation mode which would allow any
application to work properly in an iCOD environment.
Documentation For more detailed information about iCOD, see the
following documents:
• Instant Capacity On Demand (iCOD) Release Notes for Version 2.0
(B9073-90003) available on the HP-UX 11i Instant Information CD
and on the web at:
http://docs.hp.com/
• Manpages
— icod (5)
— icod_modify (1M)
— icod_notify (1M)
— icod_stat (1M)
Java Plug-In (JPI)
The Runtime Plug-in (JPI) Version 1.2.2.04Ha for HP-UX 11.0 and 11i
Java Edition allows you to utilize a version of the JRE that is different
from the JRE embedded with Netscape Navigator 4.61 or later.
Using this release of the Runtime Plug-in for HP-UX, Java Edition, you
can access the HP-UX Runtime Environment for the Java 2 Platform
from within Netscape Navigator 4.61 or later.