Headline:
The following errors occur in the swagent.log when both Workload manager and PRM are being
installed at the same time.
Defect or Error Messages:
* Installing fileset "Workload-Mgr.WLMB-RUN ,r=A.01.02" (838 of
838).
------- 07/06/01 04:02:58 EDT BEGIN swpackage SESSION
* Session started for user "root@gold48".
* Source: gold48:/var/tmp/cmscfg.7655
* Target: gold48:/var/opt/mx/depot11
* Software selections:
*
* Beginning Selection Phase.
* Reading the Product Specification File (PSF )
"/var/tmp/cmscfg.7655".
* Reading the product "CMSConfig" at line 52.
* Reading the fileset "WLMB-CMS-Tools" at line 68 .
* Selection Phase succeeded.
* Beginning Analysis Phase.
NOTE: Repackaging all of the product "CMSConfig". (The same product version
already exists in the target depot.)
WARNING: The fileset "CMSConfig.PRM-CMS-Tools" exists in the target
"/var/opt/mx/depot11", but it is not a part of the product as
defined in the source "/var/tmp/cmscfg.7655". The fileset
"CMSConfig.PRM-CMS-Tools" should be removed from the target.
WARNING: Existing filesets in the product "CMSConfig" may be obsolete
(see above). If not removed, they will remain in the target
"/var/opt/mx/depot11" as part of the product.
* Analysis Phase succeeded.
Explanation:
This is due to the fact that Workload Manager and PRM are creating the
same depot (/var/opt/mx/depot11)
Will be fixed in release A.02.00 of HP-UX WLM, scheduled for AR0302.