HP-UX 11i June 2002 Release Notes
I/0 and Networking Cards
Network Drivers
Chapter 7
147
— You can now make use of the new -v option of the irdiag command. Also, you
can use the irdfd command to perform disk firmware downloads and the
irconcheck command to perform consistency checks.
Documentation
For more information see the HP A5856A RAID 4Si PCI 4-Channel Ultra2 SCSI
Controller Installation and Administration Guide at http://docs.hp.com and the
following manpages:
• irdfd (1M) (new)
• irconcheck (1M ) (new)
• irdisplay (1M) (revised)
• irmd (1M) (revised)
• irdiag (1M) (revised)
• irm (1M)
• i2outil (1M)
HyperFabric2 PCI Fiber Adapter
new for
June 2001
HyperFabric is a high-speed network link that runs on various HP 9000 servers and
workstations. HyperFabric supports the IP network protocol stack, including TCP/IP,
UDP/IP, and NFS.
Summary of Changes
• The A6386A HyperFabric2 PCI fiber adapter is now supported on HP-UX 11i on
these HP 9000 systems:
— A400, A500, L-, N-, V-Class, Superdome, and rp8400 systems
— B1000, B2000, B2600, C3000, C3600, C3700, J5000, J5600, J6000, J6700, and
J7000 workstations
• The clic_ping command is replaced by the clic_probe command
Documentation
See the HP HyperFabric Release Notes for Application Release 0601 (part number
B6257-90029) for more information.
Performance Enhancements to the HSC FDDI Driver
HP-UX 11i includes code that enhances the HSC FDDI driver. These driver
modifications increase performance of the FDDI link by up to 20%.
The performance enhancement was done by making the driver MBLK-based, whereas
previously it was MBUF-based. Other code-path and function-call reductions have
further improved performance and scalability. These changes are not directly visible to
the user and have no effect on current documentation or support.