HP-UX 11i June 2001 Release Notes
Superdome Systems
HP Superdome Servers: New Attention Indicator Behavior (new for June 2001)
Chapter 2 47
HP Superdome Servers: New Attention
Indicator Behavior (new for June 2001)
The fruled command and Partition Manager blink the attention
indicators (LEDs) on HP Superdome cells and I/O chassis rather than
illuminating them in a steady-on state.
The SAM (/usr/sbin/sam) and Partititon Manager utilities now blink
PCI slot attention LEDs for procedures that involve locating PCI slots.
For example, the fruled -o -c2 command now causes cell 2’s attention
indicator to blink, and the fruled -o -i0/1/3 command blinks the
attention indicator for cabinet 0, I/O bay 1, chassis 3.
The /usr/sbin/rad command still provides the same functionality for
managing PCI card slot attention indicators. You should use the
rad -f attention #-#-#-# command to blink the attention LED when
locating the specified slot (
#-#-#-#
). See rad (1M) for options.
Benefits
These changes conform to the PCI Hot-Plug specification for attention
indicator states and meanings; see Table 2-2 for the states and
meanings.
Table 2-2 Attention Indicator (LED) States and Meanings
Attention LED State Meaning
OFF Normal; not selected, normal operation.
ON Attention; operational problem.
Supported for PCI card slot LEDs only.
Service is required, problems have been identified with the
component.
BLINKING Locate; user requested to locate hardware.
User has selected the hardware for use in a service operation.