HP-UX 11i Installation and Update Guide, March 2003

Updating to HP-UX 11i
How to Update to HP-UX 11i
Chapter 6120
After migrating your directory server database to NDS 6.02, you should
remove the old version of NDS using swremove. For example:
/usr/sbin/swremove J3667AA
Update Selectable Software
To update to HP-UX 11i and include additional selectable software (such
as Ignite-UX):
Step 1. As root, enter:
•CD-ROM: /usr/sbin/update-ux -x /cdrom B5725AA
•DVD: /usr/sbin/update-ux -x /dvdrom B5725AA
In the above command, update-ux installs the default HP-UX 11i OS
bundles listed on page 70, plus the Ignite-UX server bundle, B5725AA.
Step 2. Complete any post-install configuration explained in the HP-UX 11i
Release Notes available on the Instant Information CD and on
http://docs.hp.com/hpux/os/11i. In this example, to complete the
Ignite-UX server installation, see Chapter 2 in the Ignite-UX
Administration Guide.
Step 3: Update Drivers (Existing HP-UX 11i Systems)
After updating an existing 11i system to the latest 11i release, be sure to
use swinstall to update hardware drivers from the new HWEnable11i
bundle. Insert either the HP-UX 11i OE media or the latest Support
Plus CD in your local drive and enter (as root):
•CD-ROM: /usr/sbin/swinstall -x autoselect_patches=true
-s /cdrom HWEnable11i
•DVD: /usr/sbin/swinstall -x autoselect_patches=true -s
/dvdrom HWEnable11i
Step 4: Verify the Update
IMPORTANT TCOE Customers: MLIB has not been updated yet. To update MLIB,
please see “Installing MLIB (TCOE Customers)” on page 132.