HP-UX 11i December 2004 Release Notes
Table Of Contents
- HP-UX 11i December 2004 Release Notes
- 1 Finding HP-UX 11i v1 Documentation
- 2 What’s New at a Glance
- What’s in This Chapter?
- What’s New in the December 2004 Release?
- What’s New in the June 2004 Release?
- What’s New in the December 2003 Release?
- What’s New in the September 2003 Release?
- What’s New in the June 2003 Release?
- What’s New in the March 2003 Release?
- What’s New in the December 2002 Release?
- What’s New in the September 2002 Release?
- What’s New in the June 2002 Release?
- What’s New in the March 2002 Release?
- What’s New in the December 2001 Release?
- What’s New in the September 2001 Release?
- What’s New in the June 2001 Release?
- What’s New in the Original 11i v1 Release?
- 3 HP-UX 11i Version 1 Release Overview
- 4 nPartition (Hard Partition) Systems
- 5 Workstation/Server Specific Information
- What’s in This Chapter?
- Supported Systems
- Hardware Enablement
- HP Instant Support Enterprise Edition
- HP-UX V-Class Changes
- SCSI Drivers scsi3 and c720
- SCSI Driver c8xx
- Service Processor (GSP or MP)
- N4000 and rp7400 Server Functionality
- ttytype Support for the N4000 and rp7400 Console
- New stty Options
- Workstations
- 6 HP-UX 11i Version 1 Operating Environment Applications
- What’s in This Chapter?
- The HP-UX 11i Version 1 Operating Environments
- HP-UX 11i v1 Foundation Operating Environment
- Always-Installed Networking and Mass Storage Drivers
- Base VERITAS Volume Manager (VxVM)
- Codeword iCOD
- Event Monitoring Service (EMS)
- GTK+ Libraries
- HP CIFS Client and HP CIFS Server
- HP WBEM Services for HP-UX
- HP-UX Software Development Kit and Runtime Environment for the Java 2 Standard Edition (J2SE) Pla...
- HP-UX Support Tools (Diagnostics): STM, ODE, & EMS Hardware Monitors
- HP-UX Web Server Suite
- HP-UX Apache-based Web Server
- HP-UX Webmin-based Admin
- HP-UX Tomcat-based Servlet Engine
- HP-UX XML Web Server Tools
- Java for HP-UX Add-On Standard C++ Runtime Libraries for the SDK and the RTE
- Judy Libraries
- Mozilla Application Suite
- MySQL
- OpenSSL
- Partition Manager
- Perl Programming Language
- Pluggable Authentication Module (PAM) Kerberos
- Plug-In for the Java 2 Platform for Mozilla
- Servicecontrol Manager (SCM)
- Software Distributor
- Update-UX
- HP-UX 11i v1 Enterprise Operating Environment (EOE)
- HP-UX 11i v1 Mission Critical Operating Environment (MCOE)
- HP-UX 11i v1 Minimal Technical Operating Environment (MTOE)
- HP-UX 11i v1 Technical Computing Operating Environment (TCOE)
- Selectable Applications
- 7 Networking and Mass Storage Drivers
- 8 Installation
- What’s in This Chapter?
- Cold Install Changed
- Update-UX
- Software Distributor
- Multiple Target Management Capabilities Enabled
- POSIX Enhancements and Exceptions
- Change in swlist Hides Superseded Patches by Default
- 64-bit Capability Determined from System, Not /etc/.supported_bits
- CD Searched For Only When Requested
- GUI Streamlined
- Products Rather than Bundles Shown After Auto-Selection
- Software Groups Added to GUI
- Layout Version No Longer Converted Automatically
- Messages Improved or Eliminated
- Output of swlist Changed
- swpackage Produces Note Vs. Warning
- Newest Bundle Selected by Default
- control_utils File Improved
- New Environment Variable, SW_COMPATIBLE, Created
- SD-UX Changes to Patch Installation
- Documentation
- set_parms Enhanced
- 9 General System Administration and Performance Monitoring
- What’s in This Chapter?
- EnhancedMMAP Available on Software Pack
- MtIOscan11i Available on Software Pack
- NEWFUSER11i Available on Software Pack
- HP-UX Buffer Cache Tunable Parameters Deprecated
- HP-UX Newadb Available on Software Pack
- Compressed Dump Available on Software Pack
- Interrupt Migration Available on Software Pack
- Processor Sets Available on Software Pack
- New Option for top
- Changes to System Administration Manager (SAM)
- syslog File Logging Changes for su and login
- HP Process Resource Manager (PRM)
- HP Distributed Print Service Deprecated
- Diagnostics: EMS Hardware Monitors
- Improved ioscan Description Field for PCI Devices
- On Demand Solutions
- 10 Process, Threads, Memory, and Kernel Parameters
- What’s in This Chapter?
- HP-UX Gang Scheduling
- Kernel Threads vs. CMA Threads
- Large Private Data Space
- Memory Windows
- HP-UX SCA Process and Memory Management
- Dynamic Tunables
- Asynchronous Disk Pseudo Driver (async) Compatibility
- System-V InterProcess Communications (IPC)
- SCSI Queue Depth Management
- Changes to mpctl() System Call
- 11 Disk and File Management
- What’s in This Chapter?
- Portable File System (PFS) Obsoleted
- Enhanced AutoFS Available on Software Pack
- DeviceIDs Available on Software Pack
- VERITAS VxFS 3.5 Available on Software Pack
- Additional Support for Striping and Mirroring
- New Whitepaper on File and File System Sizes
- New Version of Journaled File System (JFS)
- Network File System Support on TCP/IP
- Other NFS Changes
- Mounting and Unmounting NFS File Systems Automatically Using AutoFS
- HP Fibrechannel High Availability Disk and Closure
- Fibre Channel Mass Storage Diagnostic Message and Kernel Tunable
- 12 Internet and Networking Services
- 13 Security
- What’s in This Chapter?
- HP-UX Shadow Passwords
- HP-UX Strong Random Number Generator Available on Software Pack
- Boot Authenticator for Standard Mode of HP-UX Available on Software Pack
- HP-UX Host Intrusion Detection System (HIDS)
- Generic Security Services for Developing Secure Applications
- Execute Protected Stacks
- Auditing Commands/System to be Updated
- Configurable Security Features
- Password History Feature on Trusted Systems
- Kerberos Client Software
- HP-UX Kerberos Server Version 2.0
- 14 Compatibility
- 15 Programming
- What’s in This Chapter?
- HP-UX Shared Memory Extensions Available on Software Pack
- HP-UX Software Transition Kit (STK)
- Libraries
- Miscellaneous
- The pstat_getfile() Interface Deprecated
- Transition Links Deprecated
- Perl Programming Language
- Linker and Object File Tools (ld, crt0.o, dld.sl, libdld.sl, chatr, and odump)
- Changes to the linker/dld Interface
- Instrumented Code Using PBO or +O4 Optimization
- HP DCE/9000
- Extensions to pstat()
- Changes to sendfile
- Machine Identifier Changes to confstr
- 16 Internationalization
- What’s in This Chapter?
- Deprecated Functionality
- Unicode Character Set
- Corrected Character Mappings to iconv(1) and iconv(3C)
- EURO (ISO 8859-15 Locales)
- Euro - ISO 10646/Unicode Support
- Asian System Environment (ASE)
- Enhanced Print Capabilities in the Asian System Environment
- Multibyte Support Extension and Unix98 Support
- 17 Licensing Products

Programming
Miscellaneous
Chapter 15
324
— /usr/bin/yacc -> /opt/langtools/bin/yacc
— /usr/bin/lex -> /opt/langtools/bin/lex
Perl Programming Language
See “Perl Programming Language” on page 133.
Linker and Object File Tools (ld, crt0.o, dld.sl, libdld.sl, chatr,
and odump)
new at 11i
original release
The following list summarizes the changes to linker and object file tools. Details for
several of the linker changes follow the lists.
Linker Changes
• Incremental linking supported in 64-bit ld and elfdump.
• Unix 98 (32-bit dl()* calls) supported in libdld.sl and dld.sl.
• 32-bit Filtered shared libraries supported in ld, dld.sl and in odump.
• GProf 32-bit shared library supported in crt0.o and dld.sl.
• ld +filter option creates filtered shared libraries.
• Support for ldd32, which lists dynamic dependencies of executable files or shared
libraries in dld.sl.
• Plabel cache, caches PLABELS at run-time, supported in ld and dld.sl.
• ld +dependdb and +dependdb_outputdir options generate dependency database,
ldb file.
• ld +objdebugonly (in both 32-bit and 64-bit) ignores debug information from non-
objdebug objects or archives and then proceeds in +objdebug mode.
• Special support for OGL's TLS shared library in dld (both 32- and 64-bit).
Tools Enhancements
• elfdump +ild displays incremental linking information.
• ar -x option allows modules from lib to keep datestamp.
•odump -tlssym option displays the TLS (thread) symbols.
• chatr +q3p enable/disable and q4p enable/disable option supports marking
3rd/4th quadrant for private data space.
• odump -verifyall option suppresses stub warnings on executable.
• odump -filtertable to displays the filtered shared library's implementation
libraries.