HP-UX 11i December 2004 Release Notes

Table Of Contents
Installation
Software Distributor
Chapter 8
196
Products Rather than Bundles Shown After Auto-Selection
In 11.0, GUI software selection using “Match What Target Has” or “Automatically select
patches for software installed on target” could be confusing because the products in the
bundles were not automatically marked for selection in the GUI.
The new 11i behavior provides a product-level view that shows which software has been
matched. After inspecting the results of the automatic selection, you can then continue
with the installation or change the view back to a bundle level.
See “SD-UX Changes to Patch Installation” on page 197 for details.
Software Groups Added to GUI
The -f option to swinstall, swremove, swcopy and swlist, which has allowed users to
specify collections of software through a file, has been incorporated into the GUI. New
actions have been added to allow SD-UX GUI users to save selected software in a
“Software Group” (which creates a group) and to select that “Software Group” in
subsequent sessions.
Layout Version No Longer Converted Automatically
In 11.0 SD-UX, commands automatically converted Installed Product Database (IPD)
and depot catalogs to layout version 1.0 or the layout version specified via the -x
layout_version=... option on the command line.
In 11i, no SD-UX command will automatically convert the layout version of an existing
target, IPD, or depot catalog, even if the -x layout_version=... option is specified on
the command line. To change the layout version of the IPD or depot, an explicit
swmodify command is needed to make the conversion.
To convert a 0.8 depot or root to layout version 1.0, use the following:
swmodify -a layout_version=1.0 @ <depot_or_root>
To convert a 1.0 depot or root back to layout version 0.8 use the following:
swmodify -a layout_version=0.8 @ <depot_or_root>
As a result of this, the -x layout_version option should no longer be needed except
when creating a depot that is to be in layout version 0.8 format. Then the -x
layout_version=0.8 option is needed for the swpackage and/or swcopy commands used
to initially create the depot. (By default, SD-UX commands that create depots will create
them in layout version 1.0 format.)
Messages Improved or Eliminated
To eliminate unnecessary messages—and to make remaining messages more useful in
diagnosing the problem or condition being recorded—many error, warning, and
information messages have been removed from or have changed in the SD-UX log files.
Output of swlist Changed
The output of swlist has changed in the following ways: