HP Servicecontrol Manager 3.0 Troubleshooting Guide

Servicecontrol Manager Issues
Repository Configuration Failure During Install
Chapter 3
31
Repository Configuration Failure During Install
This issue applies to HP-UX only.
Symptom The SCM install fails when you run the command:
mxinitconfig -a server
You receive the following error messages:
Performing server setup.
Configuring the repository...FAIL
Connection to the repository server failed.
Performing server unsetup.
Stopping the server daemons...OK
Unregistering managed agents
Unable to create signature -- skipping unregister
Unconfiguring Tomcat web server...OK
Removing server authentication keys...OK
Removing table of managed agents...OK
Unconfigure the repository...FAIL
Connection to the repository server failed.
Completed unsetup of the server.
An internal error occurred.
Failed to complete setup of the server.
Verification SCM cannot configure MySQL when a version of System Inventory Manager (SIM) prior
to 1.5 is already installed on the CMS. Verify that SIM version 1.0 or earlier is installed
on your CMS:
swlist | grep SysInvMgt
If version SysInvMgr B.11.xx.06 is listed, then you have SIM 1.0 installed.
Fix SIM version 1.0 and earlier cannot be installed on the same machine as SCM. You can
either:
Upgrade to SIM 1.5 and reinstall SCM.
Remove SIM and install it on another system.