Configuring HP-UX For Peripherals

62 Chapter2
Managing PCI Cards with OLAR
Performing OLAR procedures from the command line
confirm suspension.
Enter Yto continue. For example:
The following interface driver I/O node(s) will be suspended:
0/12/0/0 c720
Do you wish to continue(Y/N)? Y
#
rad returns the command prompt upon successful suspension of the
driver. If for some reason the driver instance cannot be suspended, rad
outputs an error message to console.
Step 7. Turn off power to the target slot(s):
# rad -o slot_ID
If the slot is successfully powered-down, the command prompt is
returned. At this point, the target slot’s green power LED turns off and
the amber attention LED is still flashing so that the target slot for the
new card can be more easily located on the system chassis.
Step 8. Add the target card:
a. Prepare the PCI I/O card cage for card addition:
1. Remove the front bezel
2. Extend the SPU out the back of the cabinet
3. There are two PCI I/O card cages in the SPU, a left-hand side and
a right-hand side. To add a PCI I/O card on the left-hand side of
the SPU, you may have to remove the rear door
b. Insert the new PCI I/O card to the SPU:
1. Align the PCI card with the appropriate slot.
2. Insert the PCI card into the card cage, between the
separator/extractor cards.
3. Press firmly on the PCI card to make sure it is fully seated.
4. Insert the PCI card retainer screw into the back bulkhead and
tighten.
c. Prepare the SPU to be re-inserted: