Configuring HP-UX For Peripherals

Appendix A 249
EISA Board Configuration
E/ISA Board Power-Up Messages
E/ISA Board Power-Up Messages
This section contains a listing of E/ISA board power up messages, their
potential cause, and action you can take to correct the problem.
Several messages displayed are informational only. They indicate that
configuration completed successfully.
Message: No EEPROM Data -> EISA Card ID:
eisa_id
Cause: An EISA card identified itself, but non-volatile memory
(NVM) has no configuration data for the slot.
Action: Run eisa_config to update NVM.
Message: Cannot read EISA card ID
Cause: NVM recognizes that the card exists, but cannot read
its ID.
Action: If a card is present, there is a hardware problem.
Replace the card. If a card is not present, ignore the
message.
Message: Board ID:
eisa_id
inconsistent with NVM ID:
eisa_id
Cause: The ID read from the card does not match the card ID
information stored in NVM.
Action: If board has been moved, run eisa_config in
automatic mode. If this message persists after running
eisa_config and updating NVM, replace the board. If
board has been removed, ignore the message.
Message: Bad eeprom data for board
eisa_id
Cause: An attempt to read the NVM configuration information
failed. This represents a system problem.
Action: Call your HP representative.
Message: Error initializing board
eisa_id
Cause: An attempt to initialize the card with the stored NVM
initialization data failed.