Configuring HP-UX For Peripherals

Chapter 9 231
Configuring Uninterruptable Power Systems
After Configuring the PowerTrust UPS
After Configuring the PowerTrust UPS
If adding any card or peripheral to a unit monitored by a UPS, you need
to recalculate the voltage/amperage (VA) draw.
Regardless of how many PowerTrust UPS devices are installed, only one
instance of the ups_mond daemon should be running at any time.
If you are running SupportWatch, you should include /usr/adm/syslog
among those files it monitors, in addition to /usr/bin/dmesg and
/usr/adm/diag.
A special circumstance should be noted for systems with external bus
extenders covered by a PowerTrust UPS. If for any reason, a disk in an
external bus extender loses power but the SPU to which it is configured
does not, you must wait the length of time for shutdown_timeout_mins
before cycling power to the SPU.
Troubleshooting the UPS
Error messages generated by the UPS are documented on the ups_mond
(1M) manpage.