Configuring HP-UX For Peripherals

224 Chapter9
Configuring Uninterruptable Power Systems
Planning to Configure a UPS
NOTE Do not use a standard terminal cable to connect a UPS to the serial port.
The pinouts are different.
The computer should have one dedicated MUX port for UPS
communication for each UPS configured. Additional UPS units must be
connected to additional dedicated MUX ports.
Hewlett Packard supports only 25-pin MUX ports for UPS operation. The
modem port on the MFIO (Console LAN pca), RJ45, 3-pin RS-232 and
5-pin RS-422 MUX ports are not supported for UPS operation.
For each UPS on the system, you are connecting the supplied RS-232-C
cable from the UPS to a port on a Modem Distribution Panel (MDP). The
computer console must be configured to port 0. You can connect the UPS
to port 1 on the MDP.
Software Considerations
Be sure that you have loaded the PowerTrust UPS fileset, UPS-TOOLS.
You can do this using the swinstall command. Consult the HP
OpenView Software Distributor Administrator's Guide for procedures on
loading filesets.
Note, since the connections to the UPS are through power cords and
MUX ports, ioscan will not explicitly display a UPS in its configuration;
only the MUX port is displayed.
Table 9-1 UPS Cable Pin-Outs
UPS MUX
9 pins(M) 25 pins(M)
Receive 1 3
Transmit 2 2
Gnd 9 7