HP Systems Insight Manager 7.2 Technical Reference Guide

4. Under Contents of selected version control repository, click the icon to view the contents
of the HP VCRM that you selected.
To expand the tree to display all contents, click the icon located in the upper-left corner
of the Contents of selected Version Control Repository section. Click the icon to collapse
the listings.
Select the components you want to install, and click Next.
The Select Install Options section appears. The items are installed in the order they are listed
in.
5. Optional: To reorder the items, select the item to reorder and perform one of the following
actions
Click Move Up to advance the item up.
Click Move Down to move the item down.
6. If you are installing software that is earlier than or the same version currently installed, select
Force install the agents . This option is disabled by default.
7. Check Select if upgrading FW on a system with Trusted Platform Module (TPM) enabled to
force a FW upgrade to a TPM system or I/O FW.
8. Bring systems to full power before the installation by selecting Bring systems to full power
before install. If you do not select this option, the installation is attempted and might fail
because the system was not running at full power.
To be brought to full power, the target system must support Magic Pocket technology.
If selected, target systems are brought to full power before the installation is selected.
9. Optional: Clear the Reboot systems if necessary after successful install option if you do not
want to reboot after the installation. However, the successful task status indicates that a reboot
is required to complete the update.
If you click Schedule, the Schedule Task section appears.
10. Beginning with HP SIM 6.2, the following firmware is supported through the Install Software
and Firmware task.
Online System, FPGA, ILO-3 MP and Power Monitor Firmware Windows Flash Component
for HP Integrity BL860c/BL870c/BL890c i2 Servers
Online ILO and SFW Windows Firmware Flash Component for HP Integrity rx2800 i2
Servers
Online ILO and SFW Linux Firmware Flash Component for HP Integrity rx2800 i2 Servers
Select one of the following HP SUM installation options:
Select Fail the install on system where HP VCA is not present to perform SW/FW
deployments on targets with HP VCA installed. When HP VCA is not installed, the task
fails without requesting the HP SUM for deployment.
This option is selected by default for legacy tasks. New tasks display the option Install
on systems where VCA is not present.
Select Install on system where HP VCA is not present. Use the stored sign-in credentials
for each system (must be administrator level), to utilize HP SUM to perform the SW/FW
installation using the stored sign-in credentials. This is the default option for new tasks.
Install on systems where HP VCA is not present. Use the specified administrator credentials
and enter the User Name, Password, Password (Verify), and Domain (Optional) credentials,
to utilize HP SUM to perform the SW/FW installation using single administrator username
and password.
11. Click Schedule to configure a time for the update to occur.
Installing Software and Firmware task 419