HP Systems Insight Manager 5.2 Update 2 Technical Reference Guide
3. Scroll down and select the current HP Version Control Repository Manager.
4. Click Remove to uninstall the VCRM.
Virtual machine
JVM is shutting down.
Solution:
This could happen if you have physically disconnected the Central Management Server from your
network. Restart HP SIM and the problem should correct itself.
Virtual Machine Management Pack
The HP ProLiant Essentials Virtual Machine Management Pack (HP ProLiant Essentials Virtual Machine
Management Pack) functions are not working in HP SIM.
Solution:
Attempts to log in to the Virtual Machine Management Pack plug-in for HP SIM 4.x will not succeed
if the user name contains a character that is not alphanumeric, which prevents the Virtual Machine
Management Pack functions from being used within HP SIM.
WBEM Indications
When you get a FAILED to create indication subscription” message when Subscribing
for WBEM Events on HP-UX .
Solution:
Be sure that the requirements are met and all of the software required to support indications is
installed.
On the managed system:
For HP-UX 11.11 and 11.23:
• WBEMServices A.02.00.09 at a minimum.
Note:
Patch is required for both HP-UX 11.11 and 11.23 with WBEM Services A.02.00.09 for HP
SIM to manage correctly.
• PHSS_34428 - 11.11 HP WBEM Services A.02.00.09
• PHSS_34429 - 11.23 HP WBEM Services A.02.00.09
• SFM provider module.
Run #cimprovider -ls.1.
2. Verify that the SFMProviderModule is listed.
3. The following must be installed on the system:
• SysMgmtWeb version A.2.2.2 (HP-UX Web Based System Management User Interface)
• OpenSSL A.00.09.07e.012 or later
• WBEMServices A.02.00.09
• WBEM Services CORE Product OnlineDiag B.11.11.16.xx
• EMS Version A.04.20
• STM Version A.49.10
Note: The SFM providers are not available as part of the core operating system on an old
HP-UX 11.11 installation will not work.
On HP SIM:
Confirm the target system has the correct software installed to support indication subscription and delivery.
1. Navigate to the System Page for the target system.
2. Select the System tab.
658 Troubleshooting