HP Systems Insight Manager 5.2 Update 2 Technical Reference Guide

Cause: The user name or password is incorrect.
Possible solutions:
Make sure you enter a user name and password that allow at least read access to all data in the
CIMOM.
See the CIMOM documentation for instructions on determining the appropriate user name, and how
to determine (or change) the password.
For most HP SMI-S providers the default is user name:
administrator
and password:
administrator
. Use
the .\Program Files\Hewlett-Packard\SMI-S\cimom\UserAccountsManager.bat utility
to change the password. If you run the utility without input, it displays its syntax.
For Command View EVA 5.0, the default user name is
administrator
. The password is created during
the provider installation. You can change the password with the cimuser utility, which is installed
during the provider installation.
For Command View XP Advanced Edition 1.1 and later, the default user name is
system
and the default
password is
manager
. You can add Users and change passwords through the Command View XP
Advanced Edition user interface (you must log in with a username/password that is in the
Admin
group).
Click the User Management branch, and then select Users. The user chosen for CIMOM access must
be in the
Admin
or
StorageAdmin
group.
For Windows HBAs (Emulex OEM), the default user name is
cimadmin
and the default password is
pwd580
. You can change the user name and password during the provider installation, or with the
cimuser
utility.
Error connecting with SSL=true - (CIM_ERR_INVALID_NAMESPACE)
Cause: The namespace is incorrect.
Possible solution:
Make sure you enter the correct namespace for the affected device.
Default namespaceDevice
The default for most HP arrays is root, with the following exceptions:
If you are running Command View EVA 5.0, the default namespace is root/pg_interop.
If you are running Command View XP Advanced Edition 5.0, the namespace is
root/hitachi/dm50.
If you are running Command View XP Advanced Edition 5.1, the namespace is
root/hitachi/dm51.
HP arrays
root/emulexEmulex HBAs
root/cimv2HP-UX HBAs
root/qlogicQLogic HBAs
interopBrocade switches
root/cimv2Cisco switches
interop or root/cimv2 depending on the switch modelHP switches
interopMcData switches
The output from wbemdisco lists information about the CIMOM and provider, but no storage devices are
listed
Cause: Most storage device CIMOMs require additional management software. This error usually means
the management software is not configured to manage any storage devices.
646 Troubleshooting