HP Systems Insight Manager 7.2 Release Notes
If SW/FW upgrades are failing immediately with no error code, then be sure there are no instances
of the HP SUM process already running on the CMS. Only one instance at a time can be running.
Kill off the HP SUM process and retry the operation. This includes the following tasks:
• Install Software/Firmware
• Configure or Repair Agents
• Manage System Software Wizard
• Manage SW/FW Baselines
• Track SW/FW Versions
-------------------------------------------------------------
When trying to deploy Software/Firmware on the target in offline mode (which already has HP
SPP Software/firmware components installed), the task gets completed with success status along
with the Log Target Local host is up-to-date, no updates were needed or nothing was installed
before exiting. If the target has no Software/firmware (or older versions), then the task gets
completed successfully, installing latest Software/firmware in the target.
HP Version Control Agent
When installing HP VCA through HP SIM, ignore the following error message: error while
loading shared libraries: libncurses.so.5: cannot open shared object
file: No such file or directory Starting HP Version Control Agent: OK.
-------------------------------------------------------------
Often, while installing an SPP to a Linux system, the install attempts to install components that are
not applicable to the system. These components will fail without harm, but will be logged.
WBEM indications
3PAR firmware does not support full WBEM indications. Therefore, the indication description and
event severity in HP SIM does not match the 3PAR events logs. HP recommends you use SNMP
traps.
HP Version Control Agent 9