Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30

Page 6 of 53
cpqMeAlarmSeverity
cpqMeAlarmExtendedDescription
Supporting SNMP trap description: “[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value
[cpqMeAla rmValue] >= [cpqMeAlarmRisingThreshold].”
10006 - cmathreshd
Log message: “Falling Threshold Trap”
“Alarm Variable %s” “Threshold Value %d”
“Alarm Value %d” “Alarm Sample Type %s
“Alarm Owner %s”
“Alarm Severity %d”
“Alarm Description %s”
SNMP trap: cpqMeFallingAlarmExtended - 10006 in CPQTHRSH.MIB
Symptom: Falling Threshold passed. An alarm entry has crossed its falling threshold. The instances of
those objects contained within the variable list are those of the alarm entry which generated this trap.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqMeAlarmVariable
cpqMeAlarmSampleType
cpqMeAlarmValue
cpqMeAlarmFallingThreshold
cpqMeAlarmOwner
cpqMeAlarmSeverity
cpqMeAlarmExtendedDescription
Supporting SNMP trap description: “[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value
[cpqMeAlarmValue] <= [cpqMeAlarmFal li ngThreshold].”
10007 - cmathreshd
Log message: “%s: Variable %s has value %d >= %d.”
SNMP trap: cpqMeCriticalRisingAlarmExtended - 10007 in CPQTHRSH.MIB
Symptom: Critical Rising Threshold passed. An alarm entry has crossed its critical rising threshold. The
instances of those objects contained within the variable list are those of the alarm entry which generated
this trap.
User action: None required
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqMeAlarmVariable
cpqMeAlarmSampleType
cpqMeAlarmValue
cpqMeAlarmRisingThreshold
cpqMeAlarmOwner
cpqMeAlarmSeverity
cpqMeAlarmExtendedDescription
Supporting SNMP trap description: “[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value
[cpqMeAla rmValue] >= [cpqMeAlarmRisingThreshold].”
10008 - cmathreshd
Log message: “%s: Variable %s has value %d >= %d.”
SNMP trap: cpqMeCriticalFallingAlarmExtended - 10008 in CPQTHRSH.MIB
Symptom: Critical Falling Threshold passed. An alarm entry has crossed its critical falling threshold. The
instances of those objects contained within the variable list are those of the alarm entry which generated
this trap.
User action: None required