Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 52 of 53
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
Supporting SNMP trap description: "Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort]."
18012 – cmanicd
Log message: "Connectivity Lost for adapter in slot %d, port %d."
SNMP Trap: cpqNic3ConnectivityLost – 18012 in CPQNIC.MIB
Symptom: This trap will be sent any time the status of a logical adapter changes to the Failed condition.
This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a
redundant configuration fails. This can be caused by loss of link due to a cable being removed from the
adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the
adapter, Hub, or Switch may need replacement.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
Supporting SNMP trap description: "Connectivity lost for adapter in slot [cpqNicIfPhysAdapterSlot], port
[cpqNicIfPhysAdapterPort]."
18013 – cmanicd
Log message: “Redundancy increased by adapter in slot %d, port %d."
SNMP Trap: cpqNic3RedundancyIncreased – 18013 in CPQNIC.MIB
Symptom: This trap will be sent any time a previously failed physical adapter in a connected logical
adapter group returns to the OK condition. This trap is not sent when a logical adapter group has
connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This
can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged.
User Action: None required.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
cpqNicIfLogMapAdapterOKCount
Supporting SNMP trap description: " Redundancy increased by adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort]."
18014 – cmanicd
Log message: “Redundancy Reduced by adapter in slot %d, port %d."