Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30

Page 45 of 53
User action: Check power enclosure connections or add power supplies.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosu reName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNu m
Supporting SNMP trap description: “Inadequate power to power on blade [cpqRackServerBladePosition],
in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”
22026 - cmahealthd
Log message: “Server power on via manual override.”
SNMP trap: cpqRackServerPowerOnManualOverride - 22026 in CPQRACK.MIB
Symptom: Server power on via manual override. The server blade was powered on by a manual override.
User action: None
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosu reName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNu m
Supporting SNMP trap description: “Server power on via manual override on blade
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
22027 - cmahealthd
Log message: “Rack enclosure fuse open.”
SNMP trap: cpqRackFuseOpen - 22027 in CPQRACK.MIB
Symptom: Fuse open. The fuse has been tripped.
User action: Check enclosure and/or blade power connections and reset the fuse.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosu reFuseLocation
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNu m
Supporting SNMP trap description: “Fuse open fuse [cpqRackCommonEnclosureFuseLocation], in
enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName].”
22028 - cmahealthd
Log message: “Server blade removed”
SNMP trap: cpqRackServerBladeRemoved - 22028 in CPQRACK.MIB