Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 44 of 53
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosu reName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNum
Supporting SNMP trap description: “Server power on prevented to preserve redundancy in blade
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
22023 - cmahealthd
Log message: “Server power on prevented inadequate power to power on.”
SNMP trap: cpqRackServerPowerOnFailedNotEnoughPower - 22023 in CPQRACK.MIB
Symptom: Inadequate power to power on. There is not enough power to power on the server blade.
User action: Check power connections or add power supplies.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosu reName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNu m
Supporting SNMP trap description: “Inadequate power to power on blade [cpqRackServerBladePosition],
in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”
22024 - cmahealthd
Log message: “Server power on prevented server enclosure micro-controller not found.”
SNMP trap: cpqRackServerPowerOnFailedEnclosureNotFound - 22024 in CPQRACK.MIB
Symptom: Inadequate power to power on. There is not enough power to power on the server blade.
The server enclosure micro-controller was not found.
User action: Check server enclosure connections or add power supplies.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosu reName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNu m
Supporting SNMP trap description: “Inadequate power to power on blade [cpqRackServerBladePosition],
in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”
22025 - cmahealthd
Log message: “Server power on prevented power enclosure micro-controller not found.”
SNMP trap: cpqRackServerPowerOnFailedPowerChassisNotFound - 22025 in CPQRACK.MIB
Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The
power enclosure micro-controller was not found.