Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30

Page 43 of 53
cpqRackPowerEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNu m
Supporting SNMP trap description: “The power subsystem in enclosure [cpqRackPowerEnclosu reName]
in rack [cpqRackName] is no longer redundant.”
22019 - cmahealthd
Log message: “Rack power supply detected an input voltage problem.”
SNMP trap: cpqRackPowerSubsystemLineVoltageProblem - 22019 in CPQRACK.MIB
Symptom: The rack power supply detected an input line voltage problem.
User action: Check the power input for the power supply or replace any failed power supplies as soon as
possible.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackPowerSupplyEnclosureName
cpqRackPowerSupplyPosition
cpqRackPowerSupplyFWRev
cpqRackPowerSu pplyI nputLineStatus
cpqRackPowerSupplySparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNum
Supporting SNMP trap description: “The rack power supply detected an input line voltage problem in
power supply [cpqRackPowerSupplyPosition], enclosure [cpqRackPowerSupplyEnclosureName], rack
[cpqRackName].”
22020 - cmahealthd
Log message: “Rack power subsystem overload condition”
SNMP trap: cpqRackPowerSubsystemOverloadCondition - 22020 in CPQRACK.MIB
Symptom: The rack power subsystem has an overload condition.
User action: Replace any failed power supplies as soon as possible to return the system to a redundant
state.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackPowerEnclosureName
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosu reTrapSequenceNu m
Supporting SNMP trap description: “The power subsystem in enclosure [cpqRackPowerEnclosureName]
in rack [cpqRackName] is in an overload condition.”
22022 - cmahealthd
Log message: “Server power on prevented to preserve redundancy.”
SNMP trap: cpqRackServerPowerOnFailedNotRedundant - 22022 in CPQRACK.MIB
Symptom: Server power on prevented to preserve redundancy. There is not enough power to power on
the server blade and maintain redundancy for the other blades in the enclosure.
User action: Check power connections or add power supplies.
Supporting SNMP trap data:
sysName