Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30

Page 36 of 53
SNMP trap: cpqHe3FltTolPowerRedundancyRestore - 6054 in CPQHLTH.MIB
Symptom: The fault tolerant power supplies have returned to a redundant state for the specified chassis.
User action: None required
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHeFltTol PowerSu pplyChassis
Supporting SNMP trap description: “The Power Supplies are now redundant on Chassis
[cpqHeFltTolPowerSupplyChassis].”
6055 - cmahealthd
Log message: "The Fans are now redundant on Chassis %d."
SNMP trap: cpqHe3FltTolFanRedundancyRestored - 6055 in CPQHLTH.MIB
Symptom: The Fault Tolerant Fans have returned to a redundant state for the specified chassis.
User action: None required
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
Supporting SNMP trap description: “The Fans are now redundant on Chassis [cpqHeFltTolFanChassis].”
6057 - cmahealthd
Log message: “Memory Board or Cartridge Removed”
SNMP trap: cpqHeResMemBoardRemoved - 6057 in CPQHLTH.MIB
Symptom: Memory board or cartridge removed. An Advanced Memory Protection sub-system board or
cartridge was removed from the system.
User action: Ensure the board or cartridge has memory correctly installed and reinsert the memory board
or cartridge back into the system.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHeResMemBoardSlotIndex
Supporting SNMP trap description: “Memory Board or Cartridge Removed from Slot
[cpqHeResMemBoardSlotIndex].”
6058 - cmahealthd
Log message: “Memory Board or Cartridge Inserted”
SNMP trap: cpqHeResMemBoardInserted - 6058 in CPQHLTH.MIB
Symptom: Memory board or cartridge inserted. An Advanced Memory Protection sub-system board or
cartridge has been inserted into the system.
User action: None required
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHeResMemBoardSlotIndex
Supporting SNMP trap description: “Memory Board or Cartridge Inserted into Slot
[cpqHeResMemBoardSlotIndex].”
6064 - cmahealthd
Log message: “Corrected Memory Errors Detected”
SNMP trap: cpqHe5CorrMemReplaceMemModule - 6064 in CPQHLTH.MIB
Symptom: Corrected Memory Errors Detected. The errors have been corrected, but the memory module
should be replaced. Value 0 for CPU means memory is not Processor based.
User action: None required
Supporting SNMP trap data: