Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 35 of 53
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHeFltTol PowerSu pplyChassis
cpqHeFltTolPowerSupplyBay
cpqHeFltTolPowerSupplyStatus
cpqHeFltTolPowerSupplyModel
cpqHeFltTolPowerSupplySerialNumber
cpqHeFltTolPowerSupplyAutoRev
cpqHeFltTolPowerSupplyFirmwareRev
cpqHeFltTolPowerSupplySparePartNum
cpqSiServerSystemId
Supporting SNMP trap description: “The Power Supply is Failed on Chassis [cpqHeFltTolPowerSupplyChassis],
Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model
[cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware
[cpqHeFltTolPowerSupplyFirmwareRev].”
6051 - cmahealthd
Log message: “Mirrored Memory Engaged”
SNMP trap: cpqHeResilientMemMirroredMemoryEngaged - 6051 in CPQHLTH.MIB
Symptom: Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection
subsystem has detected a memory fault. Mirrored Memory has been activated.
User action: Replace the faulty memory.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
Supporting SNMP trap description: “The Advanced Memory Protection subsystem has engaged the
online spare memory.”
6052 - cmahealthd
Log message: “Advanced ECC Memory Engaged”
SNMP trap: cpqHeResilientAdvancedECCMemoryEngaged - 6052 in CPQHLTH.MIB
Symptom: Advanced Memory Protection Advanced ECC Memory Engaged. The Advanced Memory
Protection subsystem has detected a memory fault. Advanced ECC has been activated.
User action: Replace the faulty memory.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
Supporting SNMP trap description: “The Advanced Memory Protection subsystem has engaged the
advanced ECC memory.”
6053 - cmahealthd
Log message: “Advanced XOR Memory Engaged”
SNMP trap: cpqHeResilientMemXorMemoryEngaged - 6053 in CPQHLTH.MIB
Symptom: Advanced Memory Protection XOR Engine Memory Engaged. The Advanced Memory
Protection subsystem detected a memory fault. The XOR engine has been activated.
User action: Replace the faulty memory.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
Supporting SNMP trap description: “The Advanced Memory Protection subsystem has engaged the XOR
memory.”
6054 - cmahealthd
Log message: “The Power Supplies are now redundant on Chassis %d.”