Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 25 of 53
cpqFcaLogDrvOsName
cpqFcaLogDrvFaultTol
cpqFcaLogDrvSize
Supporting SNMP trap description: “Status is now [cpqFcaLogDrvStatus].”
16023 - cmafcad
Log message: “Tape Drive Status Change: Status is now [cpqFcTapeDriveStatus] for
[cpqFcTapeDriveModel] on port [cpqFcTapeDriveScsi Bus] target [cpqFcTapeDriveScsiTarget].”
SNMP trap: cpqExtTapeDriveStatusChange - 16023 in cpqfca.mib
Symptom: External Tape Drive Status Change. The agent has detected a change in the status of an
External Tape Drive. The variable cpqFcTapeDriveStatus indicates the current tape status.
User action: If the tape is failed or offline, check the tape and all connections.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqFcTapeDriveCntlrIndex
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
cpqFcTapeDriveModel
cpqFcTapeDriveFWRev
cpqFcTapeDriveSerialNumber
cpqFcTapeDriveLocation
cpqFcTapeDriveStatus
Supporting SNMP trap description: “Status is now [cpqFcTapeDriveStatus] for a tape drive.”
16024 - cmafcad
Log message: “Tape Drive Cleaning Require. Cleaning is required for [cpqFcTapeDriveModel] on port
[cpqFcTapeDriveScsi Bus] device [cpqFcTapeDriveScsiTarget].”
SNMP trap: cpqExtTapeDriveCleaningRequired - 1 6024 in cpqfca.mib
Symptom: External Tape Drive Cleaning Required. The agent has detected a tape drive that needs to
have a cleaning tape inserted and run. This will cause the tape drive heads to be cleaned.
User action: None required
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqFcTapeDriveCntlrIndex
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun,
cpqFcTapeDriveModel
cpqFcTapeDriveFWRev
cpqFcTapeDriveSerialNumber
cpqFcTapeDriveLocation
Supporting SNMP trap description: “Cleaning is needed for tape drive.”
16025 - cmafcad
Log message: “Cleaning tape on port [cpqFcTapeDriveScsi Bus] device [cpqFcTapeDriveScsiTarget]
needs replacing.”
SNMP trap: cpqExtTapeDriveCleanTapeReplace - 1 6025 in cpqfca.mib
Symptom: External Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an
autoloader tape unit has a cleaning tape that has been fully used and needs to be replaced with a new
cleaning tape.
User action: None required