Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 23 of 53
cpqSsChassisName
cpqSsChassisTime
cpqFcaPhyDrvBusNumber
cpqFcaPhyDrvBay
cpqFcaPhyDrvStatus
cpqFcaPhyDrvModel
cpqFcaPhyDrvSerialNum
cpqFcaPhyDrvFWRev
cpqFcaPhyDrvFailureCode
Supporting SNMP trap description: “Status is now [cpqFcaPhyDrvStatus] for a physical drive on bus
[cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay].”
16017 - cmafcad
Log message: “Accelerator Board status change. Chassis name: [cpqSsChassisName], I/O slot:
[cpqFcaAccelBoxIoSlot]. Status is now [cpqFcaAccelStatus string].”
SNMP trap: cpqFca2AccelStatusChange - 1 601 7 in CPQFCA.MIB
Symptom: External Array Accelerator Board Status Change. The agent has detected a change in the
status of an Array Accelerator Cache Board. The current status is represented by the variable
cpqFcaAccelStatus.
User action: If the accelerator board status is permDisabled(5), you might need to replace the accelerator
board.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaAccelStatus
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
cpqFcaAccelErrCode
Supporting SNMP trap description: “Status is now [cpqFcaAccelStatus].”
16018 - cmafcad
Log message: “Accelerator Board Bad Data. Chassis name: [cpqSsChassisName], I/O slot:
[cpqSsChassisName]. Accelerator lost battery power. Data loss possible.”
SNMP trap: cpqFca2AccelBadDataTrap - 1 601 8 in CPQFCA.MIB
Symptom: External Array Accelerator Board Bad Data. The agent has detected an Array Accelerator
Cache Board that has lost battery power. If data was being stored in the accelerator memory when the
system lost power, the data has been lost.
User action: Verify that no data has been lost.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP trap description: “Accelerator lost battery power. Data Loss possible.”
16019 - cmafcad