Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 21 of 53
cpqSsBoxModel
cpqSsBoxSerialNumber
cpqSsBoxFltTolPwrSupplyStatus
cpqSsBoxLocationString
Supporting SNMP trap description: “Storage box power supply status changed: Status changed from
[old cpqSsBoxFltTolPwrSupplyStatus] to [new cpqSsBoxFltTolPwrSupplyStatus]”
Trap IDs: 14004-16028
14004 - cmaided
Log message: “ATA Disk Status Changes”
SNMP trap: cpqIdeAtaDiskStatusChange - 14004 in CPQIDE.MIB
Symptom: ATA Disk Status Change. The agent has detected a change in the status of an ATA disk drive.
The variable cpqIdeAtaDiskStatus indicates the current disk drive status.
User action: If the physical drive status is smartError(3) or failed(4), replace the drive.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqIdeAtaDiskControllerIndex
cpqIdeAtaDiskIndex
cpqIdeAtaDiskModel
cpqIdeAtaDiskFwRev
cpqIdeAtaDiskSerialNumber
cpqIdeAtaDiskStatus
cpqIdeAtaDiskChannel
cpqIdeAtaDiskNumber
Supporting SNMP trap description: “Status is now [cpqIdeAtaDiskStatus] for the ATA disk.”
14005 - cmaided
Log message: “IDE Logical Drive Status Changes”
SNMP trap: cpqIdeLogicalDriveStatusChange - 14005 in CPQIDE.MIB
Symptom: IDE Logical Drive Status Change. The agent has detected a change in the status of an IDE
logical drive. The variable cpqIdeLogicalDriveStatus indicates the current logical drive status.
User action: If the logical drive status is failed(5), examine the array for failed drives that need
replacement.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqIdeControllerModel
cpqIdeControllerSlot
cpqIdeLogicalDriveControllerIndex
cpqIdeLogicalDriveIndex
cpqIdeLogicalDriveStatus
Supporting SNMP trap description: “Status is now [cpqIdeLogicalDriveStatus] for the IDE logical drive.”
16002 - cmafcad
Log message: “Spare drive status change. Chassis name: [cpqSsChassisName], Bus:
[cpqFcaSpareBusNumber], Bay: [cpqFcaSpareBay]. Spare status is now [cpqFcaSpareStatus string].”
SNMP trap: cpqFcaSpareStatusChange - 1 6002 in cpqfca.mib
Symptom: External Array Spare Drive Status Change. The agent has detected a change in the status of
an External Array spare drive. The variable indicates the current spare drive status. The variable
cpqFcaSpareBusNumber indicates the SCSI bus number associated with this drive.
User action: If the spare drive status is failed, replace the drive.”
Supporting SNMP trap data: