Chapter 44-10
Drive critical
error
A critical error occurred on a
drive.
Check the
Drive Event Log from
the front panel or RMC Web-
Based Library Administrator
pages for possible causes.
Contact your service
representative.
Drive not on Fibre
Channel
Drive(s) are detected by library
controller but are not detected
by any of the Fibre Channel
interfaces.
Verify that this is your
intended configuration.
Verify that there are no broken
or bent pins on the SCSI cables.
Tighten all SCSI cables and
power cycle the library.
If problem persists, replace the
SCSI cables.
Contact your service
representative.
Firmware update
needed
A library component has
firmware that is different from
the rest of the library.
Update library firmware.
(See page 4-60.)
Library fan
failure
A library card cage fan has
failed.
Power cycle the library.
Contact your service
representative.
Magazines
missing
Library could not detect all the
magazines.
Ensure that all magazines are
present and correctly installed.
(See Removing/Replacing a
Magazine on page 2-12.)
Door open One or more tape doors are
open. The library robotics will
not move until the door is closed.
Ensure that doors are closed.
Table 4-1 Partial Availability Conditions
Library Status Cause Solution