Cartridge Access Port Installation Instructions

62104 5
Head screws. Check CAP B for rotation by manually rotating the cylindrical door. Please
note that some older models of 20/700 require only three screws. If the CAP cannot
rotate freely, realign the CAP EMI SHIELD (see Figure 2).
9. Connect CAP B motor cable to cable fastened to upper tape library door hinge. The con-
nector is labeled MB (refer to item 3 of Figure 3).
10. Connect CAP B switch cable to cable fastened to upper tape library door hinge. The con-
nector is labeled CB (refer to item 2 of Figure 3).
11. Install the magazines into the CAP with the handle facing up by guiding the notches on the
magazine into the slots on the CAP (see Figure 4).
Figure 3. CAP Motor Cables
Motor Cables (a5601a_03)
16. Switch Cable CAP B
17. Connector Labeled CB
18. Motor Cable CAP B
19. Connector Labeled MB