Troubleshooting, Removal, and Replacement
Understanding Error States
Chapter 44-12
Fibre Channel
interface failed
Fibre Channel interface failed
power-up test. (Usually due to
problems on the SCSI bus, such
as an LVDS drive or terminator
on an HVDS bus, etc.)
Verify that proper SCSI
terminators and/or tape drives
are attached to the Fibre
Channel interface, and then
reboot the library.
Power cycle the library.
Contact your service
representative.
Power supply
fault
Library detected one or more
redundant power supplies in a
failed condition.
Determine which power supply
has failed. See page 4-26 for
LED status information.
Contact your service
representative to replace the
power supply.
Table 4-1 Partial Availability Conditions