SAN Manager LM for HP-UX Release Notes

Pre-Installation
13
Installation
Pre-Installation
Install a Fibre Channel HBA Card Into Each Computer
1. Verify that the computer functions properly before installing the HBA.
2. Shut down the computer.
3. Install the HBA. For instructions, see the documentation that came with the A5158A
HBA.
4. Cable each computer to the hub or switch.
5. Power up the computer.
Pre-Installation Checklist
1. Does the computer meet SAN Manager LM’s system requirements?
2. Is the HBA installed?
3. Is the computer attached to a SAN?
4. Is the LAN up, running, and configured so it supports the LAN IP addressing scheme?
Will the IP address on the HP-UX host work with the IP addressing scheme on the
Windows NT host(s)?
Is the
Hosts
file on the Windows NT administration host updated with the HP-UX
host’s IP address? This is only necessary if DNS Services is not configured.
Is the
/etc/hosts
file on the HP-UX host updated with the correct IP address that will
support the LAN IP addressing setup?
5. Is SAN Manager LM installed and configured on at least one Windows NT host
(preferably a Windows NT primary domain controller machine) on the SAN?