Hewlett-Packard HP SureStore E Disk System FC10 User and Service Guide
100 ,VRO DWLQJ&DXVHV
Disk fault
LED is on
Critical Fault
LED on
Critical (See STM
Disk Tool)
Disk hardware is faulty. Replace the
disk.
Power supply
LED is amber
Critical Amber Critical Critical – An incompatible or defective
component caused a temporary
fault.
– Power supply hardware is faulty.
Unplug the power cord and wait for the
LED to turn off. Reinsert the power
cord. If fault persists, replace the power
supply.
Fan LED is
amber
Critical Amber Critical Critical Fan has slowed or stopped. Replace
the fan.
LCC fault
LED is on
Critical LCC
Fault
LED on
Critical Critical LCC hardware is faulty. Replace the
LCC.
LCC fault
LED is on
and the disk
system beeps
none LCC
Fault on
none none The Enclosure ID on the installed LCC
does not match the Enclosure ID on the
peer LCC. Reset the Enclosure ID and
reinsert the LCC.
GBIC fault
LED is on
Critical Tx Fail
LED on
none none – GBIC transmission circuit has failed.
– GBIC is not receiving power.
Reseat the GBIC. If problem persists,
replace GBIC. If the replacement GBIC
fails, contact HP technical support.
7DEOH 7URXEOHVKRRWLQJ7DEOHFRQWªG
Problem
Description
HWEvent
Category
LED
State
Status
Probable Cause/SolutionSAM STM