Change Page
Updated ioscan output example to include UTM. 219
Added information on reading older log files after installing the HP08
firmware and updated AM60 software.
343
Change Page
Removed all references to HP08 to reflect the decision to roll supported
controller firmware rolled back to HP03.
Multiple
Change Page
Added checksum values for HP10 firmware files and information regarding
firmware download failure.
347
Clarified procedure for binding multiple LUNs simultaneously. 287, 311
Added caution regarding powering down the array when changing the cache
DIMM amount on both controllers. Also added note regarding the DIMM
configurations for 256 MB of cache.
671
Added information on Managing the Universal Transport Mechanism (UTM) 322
Added section Gathering Performance Data 329
Updated firmware download procedures for HP10. 346
Added section Major Event Log Entries 389
Added section Interpreting Major Event Log Raw Data Output 431
Added information for RAID 0 support on HP-UX. Multiple
Added -force option for unbinding LUN 0. 315
Added section HP10 and Later Firmware Enhancements 350
Updated firmware compatibility table. 349
Updated ioscan output example to include UTM LUN (31) 219