HP SureStore E Disk Array FC60 Service Manual (A5277A)
$5',$*2IIOLQH'LDJQRVWLF 495
HP-UX Diagnostic Tools
ASC/ASCQ Stack . . . . . . . . . . . . . . 0
Error Detection Point . . . . . . . . . . . 137363456
Host ID . . . . . . . . . . . . . . . . . . 0
Array Software Revision Level . . . . . . . -1828651008
LUN Number . . . . . . . . . . . . . . . . 0
LUN Status . . . . . . . . . . . . . . . . 0
Drive Software Revision Level . . . . . . . 0
RAID Level . . . . . . . . . . . . . . . . 0
I/O Sequence Number . . . . . . . . . . . . 392
Continue ([y]/n)?
AR60DIAG> readlog controller 0 channel 1 disk 1
Supported Log Sense Pages
------------------------------------------
Page Code 2 Error Counter Page (Write) Page [Write Errors]
Page Code 3 Error Counter Page (Read) Page [Read Errors]
Page Code 5 Error Counter Page (Verify) Page [Verify Errors]
Page Code 6 Non-Medium Error Page [Non-Medium]
Page Code 37 Vendor Unique or Non SCSI-2 Standard [Vendor Unique]
Page Code 3e Vendor Unique or Non SCSI-2 Standard [Vendor Unique]
Write Errors
------------------------------------------
Errors Corrected With Possible Delays = 0
Total Errors Corrected By Applying Retries = 0
Total Errors Corrected = 0
Total Times Correction Algorithm Processed = 0
Total Bytes Processed = (0x00000011e6d7ec00)
Total Uncorrected Errors = 0
Read Errors
------------------------------------------
Errors Corrected Without Substantial Delay = 10343
Errors Corrected With Possible Delays = 0