HP SureStore E Disk Array FC60 Service Manual (A5277A)
$5',$*2IIOLQH'LDJQRVWLF 479
HP-UX Diagnostic Tools
Demand Flush Threshold . . . . . . . . . . . . 20400/256
Demand Flush Amount . . . . . . . . . . . . . 5100/256
Cache size . . . . . . . . . . . . . . . . . . 256
MBytes
Cache Block size . . . . . . . . . . . . . . . 8
Large I/O size. . . . . . . . . . . . . . . . . 1024
Cache Mirror Allocation . . . . . . . . . . . . 12800/256
AR60DIAG > describe controller 0 options settings
Controller date .........Wed Apr 21 11:15:13 1999
[Inquiry Page 0x83] Identification Parameters
---------------------------------------------
NAA = 6 (0x06) CompanyID = 41144 (0x00a0b8), VSID = 128 (0x80)
=== IEEE Extended Unique Indentifer ===
0x00 0x06 0x01 0x66 0x00 0x00 0x00 0x04
Quiescence Value = 5
AR60DIAG> describe controller 0 options ownership
Controller pair at address 8/8.8.0.6.0.0.0
---------------------------------------------
Primary Serial Number = 1T83710047
Secondary Serial Number = 1T83710065
AR60DIAG> describe controller 0 options useroptions
================= User option settings ===============
Byte Value Meaning
0x00 0x00 Enable Synchronous Negotiation . . . . . Disabled
0x01 0x00 Enable Wide Negotiation . . . . . . . . Disabled
0x02 0x03 Spin up algorithm. . . . . . . . . . . . Wait
1 minute for start cmd - then 1 drv at a time
0x03 0x32 Drive spinup delay . . . . . . . . . . . 5