HP SureStore E Disk Array FC60 Service Manual (A5277A)

4586XSSRUW7RROV0DQDJHU
7DEOH ([SHUW7RRO0HQXVDQG'HVFULSWLRQV
Menu Option Property Description
Logs View Event Log NA Displays selected event log entries
Tests Parity Scan NA Perform a parity scan on a LUN.
Utilities Bind LUN NA Bind selected disk modules into a LUN
with a specified RAID level.
Unbind LUNs NA Unbind a LUN.
Replace LUN Zero NA Unbind and rebind LUN 0
Hot Spares Create Create hot spares.
Delete Delete hot spares.
Flash Component
Lights
Drive Flash Fault LED on selected disk.
LUN Flash Fault LEDs on all disks in the
selected LUN.
Disk Enclosure Flash Fault LEDs on all disks in the
selected disk enclosure.
Array Flash Fault LEDs on all disks in the disk
array.
HP Use
Only
Array Aliasing NA Assign an alias name to the disk array.
Change LUN Owner
NA Assign the ownership of the LUN to the
other disk array controller.
Controller Mode NA Change state of disk array controller
from active to passive, or vice versa.
Drive Fail/Unfail NA Change state of a disk to FAIL or
UNFAIL.
Drive Rebuild NA Force a rebuild the specified disk.
Reset Battery Age NA Reset the battery age to 0.
Set Date and Time NA Synchronize the date and time
maintained by the disk array with that of
the host.