HP SureStore E Disk Array FC60 Service Manual (A5277A)
4220DMRU(YHQW/RJ(QWULHV
0x4003 NVSRAM Clear Received from Alt
Controller: Logged when an
NVSRAM clear message is received
from the alternate controller. No
additional data is logged. The
companion entry of
MEL_EV_ICON_NV_CLR should
also be seen in the event log along
with this entry.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4004 Quiesce Message Received from
Alt Controller: A quiescence
manager message was received from
the alternate controller.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4005 Controller Quiesce Begin:
Controller level quiescence was
begun on the controller.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4006 Alternate Controller Quiesce
Begin: Controller level quiescence
was begun on the alternate controller.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4007 Subsystem Quiesce Begin:
Subsystem level quiescence was
begun
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4008 Controller Quiesce Abort: Controller
level quiescence is aborted.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4009 Controller Quiesce Release:
Controller level quiescence is
released.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x400A Alternate Controller Quiesce
Release: Controller level quiescence
on alternate is released
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x400B Alternate Controller Removed /
Replaced: Logged when the
controller detects that the alternate
controller has been removed or
replaced.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)