HP SureStore E Disk Array FC60 Service Manual (A5277A)

0DMRU(YHQW/RJ(QWULHV 399
Managing the Disk Array
on HP-UX
0x210B Cache Synchronize Failed: Cache
synchronization between the
controllers failed. The ASC/ASCQ
value of 0x2A/0x01 is also logged
with this event.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x210C Cache Battery Failure: Cache
battery has failed. ASC/ASCQ of
0x0C/0x00 is also logged with this
event.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x210E Cache Data Loss: Logged by cache
manager when cache blocks can’t be
successfully recovered. Companion
to an ASC/ASCQ status of
0x0C/0x81.
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x210F Memory Parity Error Detected:
Logged when a memory parity error is
detected.
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x2110 Cache Memory Diagnostic Fail:
Logged when a persistent RPA
Memory Parity error is detected.
Informational
(0x0)
Failure
(0x2)
Controller
(0x8)
0x2112 Cache Battery Fully Charged:
Cache battery has transitioned to the
good state
Informational
(0x0)
Notification
(0x4)
Battery (0x9)
0x2113 Cache Battery Warning: Logged
when the cache battery is within the
specified number of weeks of failing.
The ASC/ASCQ value of 0x3F/0xD9
is also logged with this event.
Informational
(0x0)
Error (0x1) Battery (0x9)
0x2114 Alt Controller Cache Battery Fully
Charged: The alternate controllers
cache battery has transitioned to the
good state.
Informational
(0x0)
Notification
(0x4)
Battery (0x9)
0x2116 Alternate Controller Cache Battery
Fail: The alternate controllers cache
battery has transitioned to the failed
state.
Informational
(0x0)
Failure
(0x2)
Battery (0x9)