HP SureStore E Disk Array FC60 Service Manual (A5277A)

3980DMRU(YHQW/RJ(QWULHV
&DFKH0DQDJHU(YHQWV$
Event
Number Event Description Priority Category Component
0x2101 Alternate Controller Late Check In:
Logged when the alternate controller
check in late
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2102 Controller Cache Mirroring Not
Synchronized: The mirror is out of
sync with the alternate controllers
mirror.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2106 Request to Update Cache Manager
DACSTORE: A request to update the
cache managers DACSTORE area
was received.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2107 Request to Clear Cache Manager
DACSTORE: A request to clear the
cache managers DACSTORE area
was received.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2109 Controller Hardware Cache Size
Mismatch: Write back cache could
not be enabled to due different cache
sizes of the controllers in the
subsystem. ASC/ASCQ value of
0xA1/0x00 is also logged with this
event.
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x210A Caching Not Enabled or Internally
Disabled: Write back cache could not
be enabled or was internally disabled.
The ASC/ASCQ value of 0xA0/0x00
is also logged with this event.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)