HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Operating the Control Panel
Using Control Panel Menus
82
Control Panel
Shutdown
NOTE! This command requires a SCSI Reset or power cycle for the controller to become ready.
(Shutdown is a single command and has no menu items.)
Shutdown makes the array unavailable to the host. When a Shutdown is initiated, the array completes any
I/Os in progress, posts array information stored in controller NVRAM to disks in the array, then goes
offline. A Shutdown should be performed prior to the following procedures:
•
Powering off the disk array for more than a week;
•
Replacing the batteries in a controller module;
•
Moving all of the disk modules to a new array and retaining all data.
View Settings
System State Displays the system state.
Warnings Displays the warnings.
Primary Cntrl Displays the primary array controller (x/y).
SCSI ID x Displays the SCSI ID for controller x.
SCSI ID y Displays the SCSI ID for controller y.
Firmware Displays the current version of firmware for the primary array controller.
SCSI Values Displays the SCSI values for Unit Attn, Term Power, Parity, WDTR, SDTR,
DRR, and VEB.
Auto Include Displays the status of the Auto Include (Enabled/Disabled).
Auto Rebuild Displays the status of the Auto Rebuild (Enabled/Disabled).
ActivSpare Displays the status of Active Hot Spare (Enabled/Disabled).
Number of Disks Displays the current number of disks configured in the array.
Disk States Displays the current states of all disks A1–A6 and B1–B6 in the array.
Rebuild Displays the current status of the rebuild operation.
SIMMs Installed Displays the number of SIMMs currently installed in the controller indicated.
MBytes of RAM Displays the Megabytes of RAM currently installed in the controller indicated.
L-Drv States Displays the size in Megabytes of all logical drives 0 to 7 in the array.