HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

HP SureStore E Disk Array 12H Controller
Downloading Array Controller Firmware
38
Controller
Other Considerations About the Firmware Download Process
NOTE! For Windows NT Systems: Since the Download utility does not support long directory
names, it is better to change to the directory where the firmware is located first, and then the
<codefilename>
is simply the filename of the firmware. Otherwise, a path with a directory
named “Program Files” will have to be entered as its MS-DOS directory name equivalent, for
example:
download –C c:\Progra~1\AutoRAID\Fw\Model_12H_HP26.fw 000000057D22
If the array does not show up using ARMServer (arraydsp –i), you may have to re-connect to
“see” the array using the ARMServer (arraydsp –R) command, which scans the bus for all arrays.
This command can take a few seconds to execute. Once re-connected, you will “see” the array again.