HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
181
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
215/0xd7
Secondary
Controller
Failed With
Memory Error
Y
Ignore if
SIMM
configurations
do not match
SIMM
Controller
Backplane
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to some memory
error or violation. If the
memory contents on each
board does not match (in
number), this error can occur.
Additionally, if a memory
component fails, it will cause
this error.
This will occur if a different
number of SIMMs are used on
each controller.
216/0xd8
Secondary
Controller
Failed,
Communication
ECC Errors
Y
See
accompanying
errors
None A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to the inability for
the communication area of
NVRAM to be cleared of ECC
errors.
217/0xd9
Secondary
Controller
Failed To
Enable RAM
Mirroring
Y
See
accompanying
errors
None A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to the mirror not
coming to an up state within 1
second of power on.